5.16. Overriding global settings
Supercharger allows some of its global parameters to be overwritten by the user. Although these parameters have been carefully selected, at times it may be necessary to adjust them to your circumstances. For example, when the forwarder analysis or the collector analysis takes too long, you might want them to run less frequently.
These values can be changed under Settings / Overrides.
The following table contains some of the most frequently used settings:
Setting | Explanation | Default | Units |
---|---|---|---|
AutomaticRebootEnabled | When set to True, automatically reboot a controller if WEC service on it has been unhealthy for AutomaticRebootAfterWecUnhealthyMinutes minutes. | False | |
AutomaticRebootAfterWecUnhealthyMinutes | After the set minutes, automatically reboot a controller if WEC service on it has been unhealthy and AutomaticRebootEnabled is True. | 60 | minutes |
DisableGroupPolicyChecks | When set to True, group policy information will not be collected. Group policy information is used to advise you on potential problems in the group policy settings that might influence event forwarding. | False | |
DisableTrialLicenseEmails | When set to True, no warning emails will be sent about expired trial license. | False | |
ExcludeDrivesWithCapacityBelowGb | Exclude from health checks hard drives below this capacity. If 0, don't exclude any. | 0 | GB |
RecurCollectorAnalysisSeconds | How often collector analysis will run. | 900 | seconds |
RecurForwarderAnalysisSeconds | How often forwarder analysis will run. | 900 | seconds |
RecurMaintainLoadBalancersCommandSeconds | How often maintain load balancers command will run. | 3600 | seconds |
WaitForRemoteCommandsToRunSeconds | How long to wait to complete remote commands for distributed subscription operations. | 5 | seconds |